Sound like you have specified reconfiguration of the o/s on the destination in which case it would need some kind of administrative access in order to be able to set the From the Data copy type drop-down menu, select Select Volumes to copy and click Advanced. ConverterDiagnostics20130701165725.zip 182.4 K 30855Views Tags: none (add) converterContent tagged with converter, failedContent tagged with failed, windows_2003_serverContent tagged with windows_2003_server, conversionContent tagged with conversion This content has been marked as final. Stopping Converter Standalone processes during file-level cloning might cause the machine that runs the Converter Standalone server service to restart During file-level cloning of source systems that run Windows XP or http://webinweb.net/vmware-converter/vmware-converter-error-unable-to-configure-the-destination-virtual-machine.html

Top of Page Platforms You can install VMware Converter Standalone 5.5.1 on the following platforms: Windows XP Professional SP3(32-bit and 64-bit) Windows Server 2003 R2 SP2 (32-bit and 64-bit) Windows Vista from another Windows machine) to \Windows\System32\drivers folder in the mounted disk.This is a bit hackerish but easy to do: - edit settings of the VM you will mount the vmdk; add Thus any subsequent Linux P2V jobs cannot use the same static IP until this helper VM is powered off, or at least has its network interface disabled. Therefore, you cannot use previous Converter versions to convert sources that have already been converted with Converter Standalone 5.5.

Vmware Converter Failed At 98 Unable To Find The System Volume

If you need more info please let me know.VMWARE CONVERTER SERVER 8 LOGSection for VMware vCenter Converter Standalone, pid=492, version=5.1.0, build=1087880, option=Release2013-12-05T10:42:37.733-08:00 [00524 info 'Default'] Logging uses fast path: true2013-12-05T10:42:37.733-08:00 [00524 Workaround: Configure the destination virtual machine manually. I just had to figure out how to make those changes post-conversion.

In the Worker/Agent log this issue is identified by the following statement: [#### warning 'Default'] ERROR: [Mntapi_GetFirstBootDisk] more that *one* active volume found. Top of Page Linux Sources P2V conversions of SLES 9 sources cannot complete, if the root directory is located on an LVM disk Virtual machines cloned from SLES 11 SP1 sources Browse other questions tagged windows-7 vmware-vsphere vmware-vcenter vmware-converter or ask your own question. Bcdedit /deletevalue Increaseuserva If the poster gets a prize, who gets it, the person presenting it or the first author?

See the respective Readme files (readme_java.htm and readme_dotnet.htm ) for information about building and using the samples. Failed Unable To Create ' . Vstor2-mntapi20-shared Reconfig Like Show 0 Likes (0) Actions 6. Re: 98% FAILED: Unable to reconfigure the destination virtual machine. http://www.computerhope.com/issues/ch000492.htm The parameter I was interested in was the partition because I knew it was the parameter that defined which partition, if there were multiples, was the operating system partition.

Workaround: Deselect all FAT/FAT32 volumes on the Options page of the Conversion wizard. Windows 7 Boot.ini Location From your helper VM where your unbootable vmdk is mounted, using regedit.exe, highlight HKEY_LOCAL_MACHINE and choose File-> Load Hive. The following messages appear in the log file: [03200 warning 'Default'] [,0] [NFC ERROR] NfcNetTcpRead: bRead: -1
[03200 warning 'Default'] [,0] [NFC ERROR] NfcNet_Recv: requested 264, recevied only 0 bytes
[03200 Power off the destination machine.

Failed Unable To Create ' . Vstor2-mntapi20-shared Reconfig

Win srvr 2003 Aakash Jacob Jul 3, 2013 9:45 PM (in response to beetlejelly) can you goto the concerned destination on the datastore and check if the vm directory is present. It is verified that sizes smaller or equal to 2TB minus 512 MB works fine but sizes closer to 2TB might also work. Vmware Converter Failed At 98 Unable To Find The System Volume Workaround: Start the Converter Standalone agent manually: Right-click My Computer and select Manage. Vmware Converter Failed At 98 An Error Occurred During Reconfiguration Win srvr 2003 a.p.

In what cases, is it ok to use categorical predictors with many levels in regression? this contact form If your source is an APIC computer running a PIC HAL, you must configure the correct HAL on the source machine before starting the conversion. Like Show 0 Likes (0) Actions 2. The error is displayed because limited users do not have the required write permissions. Vmware Converter Fails At 98 Windows 7

By this time, its 1:30 AM and I really didn’t want to wait 90 minutes for the conversion to run again. Win srvr 2003 a.p. Conversion jobs from and to ESX hosts that are not connected to vCenter Servers fail if the number of disks on the source machine is more than nine When converting a http://webinweb.net/vmware-converter/vmware-converter-error-unable-to-remove-the-destination-virtual-machine.html If the connection port is different from the one that is being used for the already running conversion job, both jobs fail.

Workaround: Change the destination disk type to thin. Vmware Vcenter Converter Standalone Toggle navigation Products tandem Software Audit Management Business Continuity Planning Compliance Management Cybersecurity Identity Theft Prevention Internet Banking Security Phishing Policies Risk Assessment Social Media Management Vendor Management KEYS Conference Aspire Top of Page SDK Release Notes Converter Standalone SDK 5.5 Converter Standalone SDK 5.5 supports Converter Standalone 5.5.1.

On the Destination layout tab, select Split not pre-allocated or Split pre-allocated as the destination disk type.

The following error message appears in the Status line of the Task progress tab: FAILED: Unable to create a VSS snapshot of the source volume(s). Workaround: Before the conversion, enter the name of the virtual machine by using ASCII symbols. The server was built with only a 100 MB c:\ partition. Aakash ,VCA -DCV/WM/Cloud,VCP-DCV 4/5,VCAP-DCA 4 | vExpert 2014 Mark my post as "helpful" or "correct" if I've helped resolve or answered your query!

you should be able to navigate to the target location and manually create your machine by building a new Win2K3 64bit Guest and mounting the already existing VMDKs as its disks. If the intended destination is ESX, import the Workstation virtual machine to the ESX server. This is how one of the ways to handle this issues and fix it. http://webinweb.net/vmware-converter/vmware-converter-unable-to-configure-the-destination-virtual-machine.html Your registry keys that were exported need to be put back in CurrentControlSet.

Read our Case Study Question has a verified solution. Wondering if unselecting "Reconfigure destination virtual machine" will do the trick, or should I change the name and IP temporarily. Workaround 1: In case of a dual-boot machine conversion : Boot the later version of Windows (Windows Vista, Windows Server 2008, or Windows 7). After doing a bit more searching, I was able to find the following webpage that contained more in depth details about the parameters: Additional information and help with the boot.ini.

Win srvr 2003 a.p. Converter Standalone cannot detect the power state of VMware Workstation or other VMware hosted source virtual machines if they are located on a read-only network share If the source machine is Remove the BCD manager and revert the operating system to its compatible boot process. The situation that I ran into recently was because the server I tried to convert didn't have a boot.ini file but through some searches on the internet, it looks like most

Converter only checks the first IDE disk in such configurations. You cannot copy running conversion or configuration jobs If you open the Copy As New wizard for a running configuration or conversion job when the source is a virtual machine or My VMware | VMware.comSearch ActivityBrowseAll ContentBlog PostsDiscussionsDocumentsPollsBookmarksPopular tagsCommunitiesGroupsPeopleLog inRegisterHomeVMTN Forums Mobile AppsBlogsTwitterFacebookGoogle+LinkedInYouTubeGroupsPodcasts vSphere NSXVirtual SAN vCenterFusionWorkstationvExpertVMware {code} CloudCred VMUG Home > VMTN > VMware vCenter™ > VMware Converter Standalone You must restart machines that run 64-bit Windows Vista or later before re-installing Converter Standalone If you uninstall Converter Standalone from a 64-bit Windows Vista, Windows Server 2008, or Windows 7

Workaround: On the Options page of the Converter Standalone wizard, click Networks to add network adapters to the destination virtual machine. On the Ready to Complete page, click Finish to resubmit the job. The WSDL that defines the API available on Converter server. Error code: 2147754774 (0x80042316).

Note: The timeout value is measured in milliseconds.