Home > Vmware Converter > Vmware Converter Failed Unable To Configure The Destination Virtual Machine

Vmware Converter Failed Unable To Configure The Destination Virtual Machine

Contents

To do this, simply use a working VM as a helper and add an additional virtual hard disk. Then, attach all the disks to the target machine. You may get a better answer to your question by starting a new discussion. Destination virtual machine might not boot if you change the disk controller type while converting a Linux virtual machine In Linux virtual machines, the root device can be defined using the http://webinweb.net/vmware-converter/vmware-failed-unable-to-configure-the-destination-virtual-machine.html

Creation of the target virtual machine (VM) (0%-5%) Preparing to Clone the Disk (5%-6%) Cloning (6%-95%) Post-cloning (95%-97%) Customization/Reconfig (97%-99%) Install Tools/Power On (99%-100%) The conversion process may fail at any Hopefully the information in these articles will help you in converting your physical servers to virtual ones. All images for the backup of a machine must be in a single folder that contains no other images (ShadowProtect and Backup Exec System Recovery). Like Show 0 Likes (0) Actions Go to original post Actions Remove from profile Feature on your profile More Like This Retrieving data ...

Vmware Converter Failed At 98 An Error Occurred During Reconfiguration

He was perhaps busy in tackling more worthy questions. From the source server type "telnet 902". During conversion or configuration, if you choose to customize Microsoft Windows Vista and provide wrong customization information, for example an invalid serial key, the customized destination reboots repeatedly. Workaround: Specify the user name without including the domain name.

Enable centralized management of remote conversions of multiple physical servers or virtual machines simultaneously. Connect with top rated Experts 14 Experts available now in Live! In the Computer Management window, select Services and Applications > Services on the left. Vmware P2v Migration Steps Some possible causes of these types of failures can be lost network connectivity between the servers, excessive network errors and source disk problems.

Join the community of 500,000 technology professionals and ask your questions. Vmware Converter Failed At 98 Unable To Find The System Volume If it jumps to 97% quickly and fails, this usually indicates a problem with network ports, DNS resolution or a required Windows service that is not running. Privacy Please create a username to comment. For more information on „signature()" go to http://support.microsoft.com/kb/227704.

Replace the WINDOWS\Driver Cache\i386\driver.cab file in the destination virtual machine with a version of the driver.cab file that includes the missing driver from the helper virtual machine. Unable To Update Bcd On The Destination Machine's System Volume By default, Converter Standalone has a 20 minute timeout when waiting for the helper virtual machine to start up during Linux P2V conversion This might cause a Linux P2V conversion task In this Article Share this item with your network: Related Content VSphere virtual machine migration tools: vCenter ... – SearchITChannel VMware vCenter Converter: V2V and P2V migrations made... – SearchVMware How If your source is an APIC computer running a PIC HAL, you must configure the correct HAL on the source machine before starting the conversion.

Vmware Converter Failed At 98 Unable To Find The System Volume

Make sure you are using the latest version of Converter. Copy the temporary virtual machine and send it over the WAN to the remote site. Vmware Converter Failed At 98 An Error Occurred During Reconfiguration Converter Standalone does not preserve disabled network adapters during conversion of physical machine sources that run on Windows During P2V conversion of Windows source machines, Converter Standalone does not detect disabled Vmware Converter Fails At 98 Windows 7 Nevertheless, Converter Standalone copies the source volume data to the destination using block-level copying.

Subsequent P2V conversions of remote source machines that run 64-bit Windows Vista or later might fail after a successful conversion If you convert successfully a remote source machine that runs 64-bit this contact form You can move volumes between disks only if they are not Active /boot or System / volumes. (Optional) To create a new destination disk, click Add Disk. Login SearchVMware SearchServerVirtualization SearchVirtualDesktop SearchDataCenter SearchCloudComputing Topic Troubleshooting VMware products VMware ESX and ESXi administrative tips View All Backing up VMware host servers and guest OSes Creating and upgrading VMware servers In the vmware-converter-worker.log, this error generates a message similar to Error 3 (error restoring key: Unknown error 3 (0x3) (3)) restoring registry key C:\し���か�n°...\data\SKUNKWORKS_FILLER into... . Bcdedit /deletevalue Increaseuserva

Also, did leave "Reconfigure destination virtual machine" checkbox selected, 0 LVL 3 Overall: Level 3 Message Active 1 day ago Author Closing Comment by:Akulsh ID: 403953602014-10-21 Feel guilty of giving Linux P2V jobs on ESX 5.0 target hosts fail if the name of the virtual machine is not in ASCII symbols or in the Windows current system locale If the target The failure can occur at various stages in the conversion process; these stages are based on the task bar percent and are estimated values. http://webinweb.net/vmware-converter/vmware-converter-unable-to-configure-the-destination-virtual-machine.html Most of the time it’s due to the existence of a recovery partition on the physical system and the boot.ini has the wrong partition numbers in the boot parameters…easy fix.

In the Worker/Agent log this issue is identified by the following statement: [#### warning 'Default'] ERROR: [Mntapi_GetFirstBootDisk] more that *one* active volume found. Vmware Converter Logs The WSDL that defines the API available on Converter server. You cannot install vCenter Converter 4.2.1 on the same machine where you have already installed Converter Standalone 5.5 If you install Converter Standalone 5.5 and then install vCenter Converter 4.2.1 server

Load balancing will not be performed correctly when this item is running. -- __thiscall Converter::Server::Scheduler::SchedulerItemImpl::SchedulerItemImpl(const class Converter::Server::Scheduler::SchedulerItemSpec &,const int &,const class boost::shared_ptr &,const class Vmacore::Ref &,const class boost::optional

Any advice? If you change the disk controller type while converting the virtual machine, the destination virtual machine might not boot. That concludes this series of articles on using VMware Converter. Vmware Converter Stuck At 97 Percent Click Next to view a summary of the conversion job.

Win srvr 2003 a.p. I followed instructions of Luciano Patrão (disabled non-Microsoft services, etc.) and Andrew Hancock (De-selected "Power on target machine" &de-selected "Install VMware Tools on the imported machine". Reduce it if you can. http://webinweb.net/vmware-converter/vmware-converter-error-unable-to-configure-the-destination-virtual-machine.html I could make this P2V work for an old Windows 2003 server only by changing the name and IP of the server, which no one suggested here.

See the respective Readme files (readme_java.htm and readme_dotnet.htm ) for information about building and using the samples. Incapsula incident ID: 277000490084003100-171805933173015313 Request unsuccessful. Once the process fails, Converter will destroy the VM that it created automatically. Sometimes the boot disk will not be listed as the first partition.

Right-click on each and select uninstall. Limitations when converting third-party images You can use Converter Standalone to convert third-party virtual machines, system images, and backup images with the following limitations: Backups of systems with dynamic disks are Conduct a power cycling test to stay ahead of hardware failures Don't let unplanned downtime disrupt your data center. When trying to perform a conversion over a WAN link, you might experience an SSL timeout because the timeout for SSL handshakes is two minutes.

Re: 98% FAILED: Unable to reconfigure the destination virtual machine. P2V conversion was done in about 90 minutes (~12:30 AM). I ended up having to do this conversion again due to other circumstances and did the injection pre-conversion the second time and it works as well. Previous Converter versions cannot convert source machines that have Converter Standalone 5.5 agent installed on them Converter Standalone 5.5 agent is deployed on the source machine during conversion.

Attach the VMDK file containing the system folder to another Windows Server 2003 virtual machine. Also try using the FQDN of the server instead of the short name. Finally, my most important tip: Remove all non-present hardware devices. Also ensure that you are using the correct version of Converter, which supports 2003 SP2.

On the Options page of the Conversion wizard, click Data to copy in the options list. If some changes occur on the source machine (such as adding memory or hard drives) after this information is retrieved, the Conversion wizard does not show information about the changes. AK 0 LVL 118 Overall: Level 118 VMware 110 Windows Server 2003 18 Message Active 1 day ago Expert Comment by:Andrew Hancock (VMware vExpert / EE MVE) ID: 403642022014-10-06 I Workaround: Either avoid Unicode characters when assigning owner name and organization name for the destination virtual machine, or use the workaround described at: http://support.microsoft.com/kb/310441/.

Submitting a job might fail with The specified parameter was not correct:"info.owner"message If Converter Standalone is installed in a client-server mode and you have connected by using a username, which is This log file is located on the server you are converting that is running the Converter agent, and is usually named vmware-converter-0.log and is located in the C:\Windows\temp\vmware-temp directory.